Home - Products - Measurement & Analyzer Instrument - Long calibration interval cycle Portable infrared carbon dioxide analyzer
Automatic temperature compensation function to eliminate the influence of sample gas temperature change on measurement accuracy
Technical Parameters
Product Features:
a. Large-screen dot-matrix liquid crystal display, which can simultaneously display parameters such as oxygen, date, time, etc.;
b. Adopt a new type of long-life double zirconia sensor, which has the characteristics of no power consumption, high sensitivity, fast response speed and high precision; C. It can work in the air for a long time without affecting the life of the sensor;
d. The response speed is fast, and the minimum measurement is 0. 1PPm;
e. Automatic temperature compensation function to eliminate the influence of sample gas temperature change on measurement accuracy;
f. 5000 pieces of historical data are automatically stored, allowing customers to freely check historical data;
g. Powered by a large-capacity lithium battery, the continuous measurement time is more than 24 hours, and the standby time is more than 168 hours;
h. The instrument supports multi-point piecewise linear calibration to meet the accurate measurement of oxygen content in the full range;
i. Built-in imported sampling pump (optional), long life and reliable work.
Technical parameters:
Model | KS-MAI-PG201 |
Measuring principle | double zirconia |
Display mode | 128X 64 dot matrix LCD |
Measuring range | 30%/50% 100%02 |
Measurement accuracy | 0.01%(≤30%) |
0.1% (≥30%) | |
0~10PPm≤+5%FS | |
Resolution | 0.1PPm (trace)0.01% (constant) |
Repeatability | ≤+1.0%FS |
Response time | T90≤30S |
Ambient temperature | -10°C~+50"C |
Storage environment humidity | < <90%RH, non-condensing |
Working environment humidity | < 100%RH, non-condensing |
Sample gas temperature | 0°C-60°C . |
Sampling method | inlet type or air extraction type (please specify when ordering) |
Sample gas flow | 400-600mL/min |
Inlet pressure | inlet type 5kPa≤relative pressure≤200kPa (> 200kPa is recommended to install a pressure reducing valve); air extraction type-10kPa≤relative pressure≤5kPa (<5kPa, the specific negative pressure value should be specified when ordering to determine its Airway structure) |
Exhaust pressure | free emptying (under safe conditions) |
Background gas | N2 or other noble gases |
Charging power supply | AC100~240V 50/60Hz to DC12V 2.5A |
Battery capacity | 11.1V, 11AH |
Dimensions | 155mm X 260mmX340mm (HXWXD) |
Sensor life | > 5 years (under normal use conditions) |
Air connection | NPT 1/8 female thread |
Installation method | portable |